LT Switchboards

By manufacturing excellent products, KRUTI GROUP has carved out a niche for itself. All its products are manufactured with utmost precision which ensures 100% customer satisfaction. Our quality products bear the identity of our company and reflect the expertise that we possess. Further, keeping pace with the needs of the customers, Kruti continuously improves its products to maintain its distinguished market position.

We have achieved a major milestone by assembling & commissioning the first intelligent switchboard project with the implementation of IT and web enabling of the reports. 

The following design parameters are considered in detail before manufacturing of our LT switchboards.

 

  • Safety
  • Performance
  • Reliability
  • Customisation
  • Aesthetic Appeal
  • Ease of operation & maintenance
  • Cost effectiveness


General Service Condition

Design ambient temperature 50 °C
Design Relative Humidity: 60%
Rated Voltage 415V
Permissible voltage variations: +/- 10%
Rated Frequency: 50Hz
Permissible frequency variations +/- 5%
Combined voltage & frequency Variations: +/- 10% absolute
Degree of protection:
IP 52 (I less than 2500A)
IP 42 (I greater than 2500A)
System & Main Bus fault level: 25/36/50/65/85/100 kA for 1/3s
System of grounding: Solid (effective) grounding
Duty: Continuous at rated load
Control Voltage: 24V, 110V, AC/DC, 220V AC, 415V AC


Power Control Centre

Application Protection & Control of Power Distribution
Operational Current Upto 6300 A
Operational Voltage 415/690 V
Insulation Voltage  690 V
Ambient Temperature 45/50 Deg. C
Form of Separation  Form 3/4B
Type Test Performed 
Short Circuit withstand
Temp Rise Withstand
Degree of Protection
Degree of Protection IP: 54
Configuration Fixed & Draw out


Motor Control Centre

MCC's are used to control electric motors and other equipment's from a central location, with safety an reliability. The MCC's are available in Single Front and Double Front configuration.

MCC's are sheet steel modular construction and each vertical section is segregated with metallic barriers and are supplied in fully draw-out, semi draw-out and fixed version.

Each panels are extendable both side and can be coupled to main incomer breaker panels having higher depth either side. Double bended doors and covers ensure torsion free and self-adhesive gaskets make the panels dust and vermin proof.

Various configuration of motor starter in MCC:
  • Simple DOL starter
  • Star delta Starter
  • Soft starter
  • Variable Frequency drives

Outdoor / plant level installation can be done with double door arrangement for completely dust proof design.

 

Application Protection & Control of Motors
Operational Current upto 4000 A
Operational Voltage 415/690 V
Insulation Voltage 690 V
Ambient Temperature 45/50 Deg. C
Form of Separation Form 3/4B
Type Test Performed
Short Circuit withstand
Temp Rise Withstand
Degree of Protection
Degree of Protection IP: 54
Configuration Fixed & Draw out


Automatic Power Factor Correction Panel

Supply System 3 Phase, 4 Wire
Rated Service Voltage 415 V
Rated Frequency 50 Hz
kVAr Rating 50 to 3200 kVAr
No of steps upto 12
Form of Separation  2B
Degree of Protection  IP:42


Busduct

Operational Current upto 6300 A TP/TPN/FP
Type Segregated/Non segregated
Enclosure AL/GP/SS
Protection IP: 55 IP: 55
Busbar Copper/Aluminium
Arrangment Interleaved / Non interleaved
Insulators Fiber Glass reinforced plastic
Painting Epoxy powder coating
Accessories As required


DG Synchronisation System

Supply System 3 Phase, 4 Wire
Rated Service Voltage 415 V
Rated Frequency 50 Hz
PLC Configuration
Siemens S7 / GENOP
Touch Screen Panel / Computer SCADA
No. of DG Sets Synchronazation upto 12
Form of Sepreation 2B


Out-Door Type Feeder Pillar

Operational Current 6300 A
Operational Voltage 415 V
Rated Insulation Voltage 690 V
Ambient Temperature 45 Deg. C
Form of Separation Form 3B/4
Type Test Performed
Short Circuit withstand
Temp Rise Withstand
Degree of Protection
Degree of Protection IP:67 (Outdoor & double door)
Configuration Fixed